8
9900-1BC Batch Controller Manual
Batch Module Wiring
Stand-alone application Connection to a 4 to 20 mA device
Power Wiring
The 9900 MUST be powered by 10.8-35.2 VDC ONLY.
CAUTION!
DO NOT connect your 9900 to AC power.
+
Power
Supply
12 to 32 VDC
±10%
9900
Terminals
Black
Red
PWR +
PWR –
Loop +
Loop –
+
+
4 to 20 mA
Device
Blue
Black
Red
PWR +
PWR –
Loop +
Loop –
9900
Terminals
Power
Supply
12 to 32 VDC
±10%
Common
Start
Stop
Resume
Inhibit*
*Wire an external input as override
for preventing batch from starting.
Connect an external button or keypad (not supplied)
to remotely control the 9900-1BC by wiring the
Batch Module as shown.
3-9900.397
Batch Module
Start
Resume
Common
Stop/Inhibit